On the right the distillate, on the left the concentrate

Evaporation of wastewater containing penetrant liquid

Year
2025
Sector
APPLICATION:

Vacuum evaporation of wastewater containing penetrant liquid.

DESCRIPTION:

The test is performed on wastewater from the washing of parts on which penetrant liquid had been previously applied. The sample was subjected to a vacuum evaporation test in order to verify the percentage of recoverable distilled water and the characteristics of the concentrate.

TECNICHAL DATA:
PARAMETERS
PRE-TEST DISTILLATE
pH 6,6 6
EC 270 µS/cm (20°C) < 10 µS/cm (20°C)
COD 11 mg/l O₂
HIGHLIGHTS:
  • Evaporation under vacuum at 35°C
  • Recovery of 90% of the volume as distilled water
  • Formation of a concentrate at 10% of the volume, which appears as a pumpable liquid without bottom body and not encrusting

Other case history